Achievable testing functions
- Testable single cell active area: 1~50 cm²
- Monitoring of cell current and voltage
- Polarization curve testing capability
- Durability testing
- Sensitivity testing
- Water circuit temperature, flow, and pressure control
- Automatic water replenishment function
- Water circuit conductivity monitoring
- One-click startup and automatic operation
- Custom script functionality
- Employing a two-stage separation technology combining vertical gravity and condensation to achieve efficient gas-liquid separation
- Equipped with three-stage constant temperature control technology, ensuring the temperature accuracy entering the electrolyzer is maintained within ≤±1°C in steady-state conditions
Product Advantages and Features
- Compact design, easy to operate.
- Ready for testing immediately upon startup, with no long waiting time required.
- Offers the most stable and reliable performance, meeting customers’ long-term testing needs.
- Equipped with multi-stage automatic safety protection features.
- The power supply features multiple operating modes, including CC, CV, and CP, as well as protection functions such as OCP, CVP, and OPP.
- Exclusive upper-level computer operation software with powerful monitoring capabilities.
- Customizable scripts for simple and convenient operation.
- Capable of data recording and analysis, facilitating post-test data processing.
Content | Parameters | Notes | |||
Single-channel Power Supply Power | ≤500W | ||||
Single-channel Current Range | 0~100A (Resolution: 10mA) | ||||
Single-channel Voltage Range | 0~20V(Resolution:1mV) | ||||
Current Setting Precision | ≤0.1%+0.1%F.S | ||||
Voltage Setting Precision | ≤0.05%+0.05%F.S | ||||
Single-channel Anode Recirculating Water Flow Rate | 40~400ml/min | ||||
Recirculating Water Flow Control Precision | 2.5 | ||||
Anode Recirculating Water Temperature | RT+5~90℃ | ||||
Conductivity Control | ≤0.3um/cm | ||||
Temperature Control Precision | ≤±1℃ | ||||
Preheating Rate | ≥5℃/min | ||||
Single-channel Maximum Hydrogen Flow Rate Range | 0.7L/min | ||||
Single-channel Maximum Oxygen Flow Rate Range | 0.35L/min | ||||
Cathode Backpressure Range | Ambient Pressure | ||||
Ambient Operating Temperature | 0~45℃ | ||||
Communication Interface | LAN | ||||
Communication Protocol | ModbusTCP、ModbusRTU、SCPI、S7 | ||||
Number of Channels | 1CH | 4CH | 8CH | 32CH | |
Model Number | BP-1C | BP-4C | BP-8C | BP-32C | |
Power Supply | 220V/50HZ | 380V/50HZ | 380V/50HZ | 380V/50HZ | |
“Equipment Dimensions (Width × Depth × Height, mm)” | ~360*520*450 | 1000*1300*1900 | 1500*1300*1900 | 4000*2020*2050 | Subject to adjustment based on actual needs. |