Since the company’s founding in 2019, our testing equipment BU has led the development and use of advanced test stations, ensuring the performance and reliability of our PEM electrolysis technologies. These in-house developed test stations deliver comprehensive and rigorous testing solutions for membrane electrode assemblies and catalysts by simulating real operating conditions, enabling us to optimize product performance and durability.
- Customization and Flexibility: Our test stations are designed to accommodate a wide range of MEA sizes and specifications, ensuring that each product meets the highest standards.
- Advanced Testing Capabilities: Equipped with state-of-the-art technology, our stations conduct long-duration tests, performance evaluations, and durability assessments.
- Data-Driven Insights: Leveraging advanced analytics, our test stations provide valuable insights that drive continuous improvement in product development.
BA Series
UA Series
HA Series
Product Full Table
product series | channel number | single channel standard power | Product version | main function | |
B Base (<10KW) | 1 | ≤500W | BP/A-1C | 1) achieve electrolysis cell performance test, sensitivity test, durability test 2) monitoring and displaying water temperature, pressure, flow rate, voltage, current and etc. | |
4 | BP/A-4C | ||||
8 | BP/A-8C | ||||
32 | BP/A-32C | ||||
U Upgrade (<10KW) | 1 | <10kW | UP/A-1C | 1) builds upon B series 1) with additional electro-chemical test, hydrogen in oxygen test, and potentiostat test capabilities 2) builds upon B series 2) with additional hydrogen in oxygen, oxygen in hydrogen, oxygen flow rate, hydrogen flow rate 3) enable anode/cathode back pressure test (max 40bar), differential pressure test, equal pressure test, and ambient pressure tests 4) N2 purging available for anode & cathode | |
4 | UP/A-4C | ||||
8 | UP/A-8C | ||||
32 | UP/A-32C | ||||
H High-power(≥10KW) | 1 | 10kW | HP/A1C-10 | same as U series | 2Nm³ |
~50kW | HP/A1C-50 | 10Nm³ | |||
~100kW | HP/A1C-100 | 20Nm³ | |||
4 | 10kW | HP/A4C-10 | 2Nm³ | ||
8 | 10kW | HP/A8C-10 | 2Nm³ |
Our AEM Series
Base (<10kW) | Upgrade (<10kW) | High-power (≥10kW) | |||||||||
Single channel power range | ≤500W | <10KW | 10~15kW | 50~75kW | 100~150kW | ||||||
Single channel current range | 0~100A(resolution 10mA) | 0~400A | 0~510A | 0~2000A | 0~4000A | ||||||
Single Channel voltage Range | 0~20V(resolution 1mV) | 0~32V | 0~80V | ||||||||
Current Setting accuracy | ≤0.1%+0.1%F.S. | ||||||||||
Voltage Setting accuracy | ≤0.05%+0.05%F.S. | ||||||||||
Single-channel anode circulating water flow | 40~400mL/min | 40~4000mL/min | 0.2~20L/min | 0.2~2.5m³/h | 0.5~5m³/h | ||||||
Anode circulating water temperature | RT+5~90℃ | ||||||||||
Conductivity control | ≤10 concentraction of lye | ||||||||||
Temperature control precision | ≤±1℃ | ||||||||||
Preheating rate | ≥5℃/min | ≥3℃/min | |||||||||
Maximum hydrogen flow range per channel | 0.7NL/min | 0~28NL/min | 50NL/min | 15Nm³/h | 30Nm³/h | ||||||
Maximum oxygen flow range per channel | 0.35NL/min | 0~14NL/min | 25NL/min | 7.5Nm³/h | 15Nm³/h | ||||||
Hydrogen&oxygen flow range measurement accuracy | N/A | ≤0.8%+0.2%F.S. | |||||||||
Cathode back pressure range | ambient pressure | ≤4MPa | |||||||||
Pressure control accuracy (steady state) | N/A | ≤0.25%F.S. | |||||||||
Single cell automatic patrol range | ≤±5V | ||||||||||
Voltage patrol precision | ±1mV | ||||||||||
Online monitoring of hydrogen concentration in oxygen | 0~5%VOL | ||||||||||
Hydrogen in oxygen measurement precision | ≤±1%F.S. | ||||||||||
Online monitoring of oxygen concentration in hydrogen | 0~5%VOL | ||||||||||
Oxygen in Hydrogen measurement accuracy | ≤±1%F.S. | ||||||||||
Working temperature | 0~45℃ | ||||||||||
Communication Interface | LAN | ||||||||||
Communication protocol | ModbusTCP、ModbusRTU、SCPI、S7 | ||||||||||
Power supply | 220V/50HZ | 380V/50Hz | 380V/50Hz | 380V/50Hz | |||||||
Moddel | BA-1C | BA-1/4/8/32C | UA-1/4/8/32C | HA1C-10 | HA1C-50 | HA1C-100 | |||||
Number of channels | 1/4/8/32CH | 1/4/8/32CH | customized |